GfA door control panels used with GfA ELEKTROMATEN are high-performance drive systems for nearly all door types.
-
Door controls
Door controls
-
WS
Reversing contactor controls WS
-
WS 900 2 reversing contactors
Technical data
Technical data
Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
▪ 3~230 V, PE; 3~400 V, PEOperating frequency: 50 Hz / 60 Hz Control voltage: 24 V AC Mains supply for
external loads:24 V / 1000 mA Dimensions W x H x D: 145 x 101 x 209 mm 2 Contactors 24 V for: Mechanical limit switch NES Downloads
-
WS 900 3 reversing contactors
Technical data
Technical data
Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
▪ 3~230 V, PE; 3~400 V, PEOperating frequency: 50 Hz / 60 Hz Control voltage: 24 V AC Mains supply for
external loads:24 V / 1000 mA Dimensions W x H x D: 145 x 101 x 209 mm 3 Contactors 24 V for: Mechanical limit switch NES Downloads
-
WS 900 2 reversing contactors
-
TS
Door controls TS
with integrated three push button and digital display
-
TS 959
Technical data
Technical data
Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
▪ 3~230 V, PE; 3~400 V, PEOperating frequency: 50 Hz / 60 Hz Dimensions W x H x D:
with mains switch:▪ 155 x 386 x 90 mm
▪ 155 x 386 x 117 mmHold-to-run control for: ▪ Digital limit switch DES
▪ Mechanical limit switch NESDownloads
-
TS 970
Technical data
Technical data
Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
▪ 3~230 V, PE; 3~400 V, PEOperating frequency: 50 Hz / 60 Hz Mains supply for
external loads:24 V / 180 mA Dimensions W x H x D
with mains switch:▪ 155 x 386 x 90 mm
▪ 155 x 386 x 117 mmUBS modules: 1 Relay contacts: 1 Automatic control for: ▪ Digital limit switch DES
▪ Mechanical limit switch NESDownloads
-
TS 971
Technical data
Technical data
Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
▪ 3~230 V, PE; 3~400 V, PEOperating frequency: 50 Hz / 60 Hz Mains supply for
external loads:24 V / 350 mA or
24 V / 1000 mADimensions W x H x D
with mains switch:▪ 155 x 386 x 90 mm
▪ 155 x 386 x 117 mmUBS modules: 1 Relay contacts: 2 Automatic control for: ▪ Digital limit switch DES
▪ Mechanical limit switch NESDownloads
-
TS 981
Technical data
Technical data
Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
▪ 3~230 V, PE; 3~400 V, PEOperating frequency: 50 Hz / 60 Hz Mains supply for
external loads:24 V / 1000 mA Dimensions W x H x D: 190 x 300 x 115 mm UBS modules: 5 Relay contacts: 2 Control with traffic
management for:Digital limit switch DES Downloads
-
TS 970-XL
Technical data
Technical data
Mains supply: 3N~400 V Operating frequency: 50 Hz / 60 Hz Mains supply for
external loads:24 V / 180 mA Dimensions W x H x D: 300 x 400 x 165 mm UBS modules: 1 Relay contacts: 1 Automatic control for: ▪ Digital limit switch DES
▪ Mechanical limit switch NESFeatures: ▪ Space for additional devices
▪ 4-pin main switch
▪ 3 DIN mounting rails
▪ 6 x M20 cable glandsDownloads
-
TS 971-XL
Technical data
Technical data
Mains supply: 3N~400 V Operating frequency: 50 Hz / 60 Hz Mains supply for
external loads:24 V / 350 mA or
24 V / 1000 mADimensions W x H x D: 300 x 400 x 165 mm UBS moduels: 1 Relay contacts: 2 Automatic control for: ▪ Digital limit switch DES
▪ Mechanical limit switch NESFeatures: ▪ Space for additional devices
▪ 4-pin main switch
▪ 3 DIN mounting rails
▪ 6 x M20 cable glandsDownloads
-
TS 981-XL
Technical data
Technical data
Mains supply: 3N~400 V Operating frequency: 50 Hz / 60 Hz Mains supply for
external loads:24 V / 1000 mA Dimensions W x H x D: 300 x 400 x 165 mm UBS modules: 5 Relay contacts: 2 Automatic control for: Digital limit switch DES Features: ▪ Space for additional devices
▪ 4-pin main switch
▪ 3 DIN mounting rails
▪ 6 x M20 cable glandsDownloads
-
GfA-Stick
Technical data
Technical data
Usage: The memory of the door control can be read out and displayed via Bluetooth® using the GfA-Stick and the GfA+ App. For door controls: ▪ TS 959
▪ TS 970
▪ TS 971
▪ TS 970-XL
▪ TS 971-XLRequirements: ▪ Mobile device with Bluetooth 4.0
▪ Installed GfA+ AppPart no.: 20003696 Downloads
-
TS 959
-
WS
-
Dock leveller controls
Dock leveller controls
Dock levellers are used for loading and unloading of vehicles. They allow a flexible height adjustment between building and cargo space of the vehicle.
GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. In addition to the standard "extend and retract" functions, programmable relay contacts allow for numerous safety functions and other additional functions.
-
LB 700 for hinged wedge lip
Controls for dock levellers with hinged wedge lip
-
LB 700 HL Standard
Technical data
Technical data
Additional
functions:▪ Without Supply voltage: 3~230 V, PE / 3N~400 V, PE Operating frequency: 50 Hz P Hydraulic unit: 1,5 kW Valve voltage: 24 V DC Max. valve current: 1,0 A P traffic lights: 40 W P loading Zone lighting: 150 W Dimensions B x H x T: 189 x 254 x 143 mm Downloads
-
LB 700 HL Standard
-
LB 700 for extendible lip
Controls for dock levellers with extendible lip
-
LB 700 EL Standard
Technical data
Technical data
Additional
functions:▪ Without Supply voltage: 3~230 V, PE / 3N~400 V, PE Operating frequency: 50 Hz P Hydraulic unit: 1,5 kW Valve voltage: 24 V DC Max. valve current: 1,0 A P traffic lights: 40 W P loading Zone lighting: 150 W Dimensions B x H x T: 189 x 254 x 143 mm Downloads
-
LB 700 EL Standard
-
LB 700 for hinged wedge lip
-
TS Dock leveller controls UK
Dock leveller controls UK
-
Hinged Lip combined control device
Controls for dock levellers with hinged wedge lip
-
HL combined control device
Technical data
Technical data
Part: TS Control: Extra's CC61085 TS 959 None CC61099 TS 959 with mimic lights CC61100* TS 971 with mimic lights CC61181 TS 970 None CC61182 TS 971 None *ILLUSTRATED
Downloads
-
HL combined control device
-
Telescopic Lip combined control device
Controls for dock levellers with extendible lip
-
TL combined control device
Technical data
Technical data
Part: TS Control: Extra's: CC61160 TS 959 None CC61161 TS 959 with mimic lights CC61162 TS 971 with mimic lights *CC61100 ILLUSTRATED
Downloads
-
TL combined control device
-
TS + LB Custom length cables
Custom length cables
-
Custom length cable w M40/M20 DES
Technical data
Technical data
Part Number: Part: Description: 20003955 00150 GE23955/015 1.5m cable with M40/M20 gland (DES) 20003955 00300 GE23955/030 3m cable with M40/M20 gland (DES) 20003955 00500 GE23955/050 5m cable with M40/M20 gland (DES) 20003955 00700 GE23955/070 7m cable with M40/M20 gland (DES) 20003955 00900 GE23955/090 9m cable with M40/M20 gland (DES) 20003955 01300 GE23955/130 13m cable with M40/M20 gland (DES) Other lengths are available on request, please contact sales for more information
Downloads
-
Custom length cable w M40/M20 NES
Technical data
Technical data
Part Number: Part: Description: 20004117 00300 GE24117/030 3m cable with M40/M20 gland (NES) 20004117 00500 GE24117/050 5m cable with M40/M20 gland (NES) 20004117 00700 GE24117/070 7m cable with M40/M20 gland (NES) 20004117 00900 GE24117/090 9m cable with M40/M20 gland (NES) 20004117 01300 GE24117/130 13m cable with M40/M20 gland (NES) Other lengths are available on request, please contact sales for more information
Downloads
-
Custom length cable w M40/M20 DES
-
Hinged Lip combined control device