GfA door control panels used with GfA ELEKTROMATEN are high-performance drive systems for nearly all door types.
GfA door control panels used with GfA ELEKTROMATEN are high-performance drive systems for nearly all door types.
Mains supply: | ▪ 1N~230 V, PE; 3N~400 V, PE ▪ 3~230 V, PE; 3~400 V, PE |
Operating frequency: | 50 Hz / 60 Hz |
Control voltage: | 24 V AC |
Mains supply for external loads: |
24 V / 1000 mA |
Dimensions W x H x D: | 145 x 101 x 209 mm |
2 Contactors 24 V for: | Mechanical limit switch NES |
Mains supply: | ▪ 1N~230 V, PE; 3N~400 V, PE ▪ 3~230 V, PE; 3~400 V, PE |
Operating frequency: | 50 Hz / 60 Hz |
Control voltage: | 24 V AC |
Mains supply for external loads: |
24 V / 1000 mA |
Dimensions W x H x D: | 145 x 101 x 209 mm |
3 Contactors 24 V for: | Mechanical limit switch NES |
with integrated three push button and digital display
Mains supply: | ▪ 1N~230 V, PE; 3N~400 V, PE ▪ 3~230 V, PE; 3~400 V, PE |
Operating frequency: | 50 Hz / 60 Hz |
Dimensions W x H x D: with mains switch: |
▪ 155 x 386 x 90 mm ▪ 155 x 386 x 117 mm |
Hold-to-run control for: | ▪ Digital limit switch DES ▪ Mechanical limit switch NES |
Mains supply: | ▪ 1N~230 V, PE; 3N~400 V, PE ▪ 3~230 V, PE; 3~400 V, PE |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 180 mA |
Dimensions W x H x D with mains switch: |
▪ 155 x 386 x 90 mm ▪ 155 x 386 x 117 mm |
UBS modules: | 1 |
Relay contacts: | 1 |
Automatic control for: | ▪ Digital limit switch DES ▪ Mechanical limit switch NES |
Mains supply: | ▪ 1N~230 V, PE; 3N~400 V, PE ▪ 3~230 V, PE; 3~400 V, PE |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 350 mA or 24 V / 1000 mA |
Dimensions W x H x D with mains switch: |
▪ 155 x 386 x 90 mm ▪ 155 x 386 x 117 mm |
UBS modules: | 1 |
Relay contacts: | 2 |
Automatic control for: | ▪ Digital limit switch DES ▪ Mechanical limit switch NES |
Mains supply: | ▪ 1N~230 V, PE; 3N~400 V, PE ▪ 3~230 V, PE; 3~400 V, PE |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 1000 mA |
Dimensions W x H x D: | 190 x 300 x 115 mm |
UBS modules: | 5 |
Relay contacts: | 2 |
Control with traffic management for: |
Digital limit switch DES |
Mains supply: | 3N~400 V |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 180 mA |
Dimensions W x H x D: | 300 x 400 x 165 mm |
UBS modules: | 1 |
Relay contacts: | 1 |
Automatic control for: | ▪ Digital limit switch DES ▪ Mechanical limit switch NES |
Features: | ▪ Space for additional devices ▪ 4-pin main switch ▪ 3 DIN mounting rails ▪ 6 x M20 cable glands |
Mains supply: | 3N~400 V |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 350 mA or 24 V / 1000 mA |
Dimensions W x H x D: | 300 x 400 x 165 mm |
UBS moduels: | 1 |
Relay contacts: | 2 |
Automatic control for: | ▪ Digital limit switch DES ▪ Mechanical limit switch NES |
Features: | ▪ Space for additional devices ▪ 4-pin main switch ▪ 3 DIN mounting rails ▪ 6 x M20 cable glands |
Mains supply: | 3N~400 V |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 1000 mA |
Dimensions W x H x D: | 300 x 400 x 165 mm |
UBS modules: | 5 |
Relay contacts: | 2 |
Automatic control for: | Digital limit switch DES |
Features: | ▪ Space for additional devices ▪ 4-pin main switch ▪ 3 DIN mounting rails ▪ 6 x M20 cable glands |
Mains supply: | 3N~400 V |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 350 mA |
Dimensions W x H x D: | 400 x 400 x 200 mm |
UBS moduels: | 1 |
Relay contacts: | 2 |
Automatic control for: | ▪ Digital limit switch DES ▪ Mechanical limit switch NES |
Features: | ▪ Space for additional devices ▪ 4-pin main switch ▪ 3 DIN mounting rails ▪ 8 cable glands |
Part no.: | ▪ (1) 20097199.00001 (V2A) ▪ (1) 20097199.00002 (V4A) ▪ (2) 20097199.00004 (steel) |
Mains supply: | 3N~400 V |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: |
24 V / 1000 mA |
Dimensions W x H x D: | 400 x 400 x 200 mm |
UBS moduels: | 5 |
Relay contacts: | 2 |
Automatic control for: | Digital limit switch DES |
Features: | ▪ Space for additional devices ▪ 4-pin main switch ▪ 3 DIN mounting rails ▪ 8 cable glands |
Part no.: | ▪ (1) 20098199.00001 (V2A) ▪ (1) 20098199.00002 (V4A) ▪ (2) 20098199.00004 (steel) |
Usage: | The memory of the door control can be read out and displayed via Bluetooth® using the GfA-Stick and the GfA+ App. |
For door controls: | ▪ TS 959 ▪ TS 970 ▪ TS 971 ▪ TS 970-XL ▪ TS 971-XL |
Requirements: | ▪ Mobile device with Bluetooth 4.0 ▪ Installed GfA+ App |
Part no.: | 20003696 |
Door controls for the North American market
Mains supply: | 230 V, 460 V, 575 V |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: | 24 V / 500 mA |
Dimensions W x H x D | 340 x 235 x 125 mm |
Relay contacts: | 2 |
Automatic Control for: | Digital limit switch DES |
Mains supply: | 230 V, 460 V, 575 V |
Operating frequency: | 50 Hz / 60 Hz |
Mains supply for external loads: | 24 V / 500 mA |
Dimensions W x H x D | 500 x 500 x 210 mm |
Relay contacts: | 2 |
Automatic Control for: | Digital limit switch DES |
Options: | ▪ In a steel sheet housing ▪ In a steel sheet housing +control device ▪ In a steel sheet housing +control device +mains switch |
Dock levellers are used for loading and unloading of vehicles. They allow a flexible height adjustment between building and cargo space of the vehicle.
GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. In addition to the standard "extend and retract" functions, programmable relay contacts allow for numerous safety functions and other additional functions.
Additional functions: |
▪ Without |
Supply voltage: | 3~230 V, PE / 3N~400 V, PE |
Operating frequency: | 50 Hz |
P Hydraulic unit: | 1,5 kW |
Valve voltage: | 24 V DC |
Max. valve current: | 1,0 A |
P traffic lights: | 40 W |
P loading Zone lighting: | 150 W |
Dimensions B x H x T: | 189 x 254 x 143 mm |
Additional functions: |
▪ Shelter |
Supply voltage: | 3~230 V, PE / 3N~400 V, PE |
Operating frequency: | 50 Hz |
P Hydraulic unit: | 1,5 kW |
Valve voltage: | 24 V DC |
Max. valve current: | 1,0 A |
P traffic lights: | 40 W |
P loading Zone lighting: | 150 W |
Dimensions B x H x T: | 189 x 254 x 143 mm |
Shelter: For controlling a door seal. |
Additional functions: |
▪ Without |
Supply voltage: | 3~230 V, PE / 3N~400 V, PE |
Operating frequency: | 50 Hz |
P Hydraulic unit: | 1,5 kW |
Valve voltage: | 24 V DC |
Max. valve current: | 1,0 A |
P traffic lights: | 40 W |
P loading Zone lighting: | 150 W |
Dimensions B x H x T: | 189 x 254 x 143 mm |
Additional functions: |
▪ Shelter |
Supply voltage: | 3~230 V, PE / 3N~400 V, PE |
Operating frequency: | 50 Hz |
P Hydraulic unit: | 1,5 kW |
Valve voltage: | 24 V DC |
Max. valve current: | 1,0 A |
P traffic lights: | 40 W |
P loading Zone lighting: | 150 W |
Dimensions B x H x T: | 189 x 254 x 143 mm |
Shelter: For controlling a door seal. |