Skip navigation
  • Menu
    • Home
    • About us
    • Meet the team
    • News
    • Videos
    • Newsletters
    • Resources
    • Contact
    • Training
    • Vacancies
  • Products
  • Portal
 
  • Door controls

    Door controls

    GfA door control panels used with GfA ELEKTROMATEN are high-performance drive systems for nearly all door types.

    • WS

      Reversing contactor controls WS

      • WS 900  2 reversing contactors

        Technical data

        Technical data

        Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
        ▪ 3~230 V, PE; 3~400 V, PE
        Operating frequency: 50 Hz / 60 Hz
        Control voltage: 24 V AC
        Mains supply for
        external loads:
        24 V / 1000 mA
        Dimensions W x H x D: 145 x 101 x 209 mm
        2 Contactors 24 V for: Mechanical limit switch NES
        Downloads
        WS + TS Overview (184.8 KiB)
        Catalogue sheet (306.5 KiB)
        Installation drawing (258.8 KiB)
        Installation instructions (251.1 KiB)
      • WS 900  3 reversing contactors

        Technical data

        Technical data

        Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
        ▪ 3~230 V, PE; 3~400 V, PE
        Operating frequency: 50 Hz / 60 Hz
        Control voltage: 24 V AC
        Mains supply for
        external loads:
        24 V / 1000 mA
        Dimensions W x H x D: 145 x 101 x 209 mm
        3 Contactors 24 V for: Mechanical limit switch NES
        Downloads
        WS + TS Overview (184.8 KiB)
        Catalogue sheet (306.5 KiB)
        Installation drawing (258.8 KiB)
        Installation instructions (258.4 KiB)
    • TS

      Door controls TS

      with integrated three push button and digital display

      • TS 959

        Technical data

        Technical data

        Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
        ▪ 3~230 V, PE; 3~400 V, PE
        Operating frequency: 50 Hz / 60 Hz
        Dimensions W x H x D:
        with mains switch:
        ▪ 155 x 386 x 90 mm
        ▪ 155 x 386 x 117 mm
        Hold-to-run control for: ▪ Digital limit switch DES
        ▪ Mechanical limit switch NES
        Downloads
        TS + WS Overview (184.8 KiB)
        Catalogue sheet (2.4 MiB)
        Installation drawing (733.1 KiB)
        Installation instructions to 12/2019 (≤SW 1.1) (2.2 MiB)
        Installation instructions from 01/2020 (SW 3.0) (1.7 MiB)
        Instructions to the GfA-Stick (1.3 MiB)
        Fault guide (331.2 KiB)
      • TS 970

        Technical data

        Technical data

        Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
        ▪ 3~230 V, PE; 3~400 V, PE
        Operating frequency: 50 Hz / 60 Hz
        Mains supply for
        external loads:
        24 V / 180 mA
        Dimensions W x H x D
        with mains switch:
        ▪ 155 x 386 x 90 mm
        ▪ 155 x 386 x 117 mm
        UBS modules: 1
        Relay contacts: 1
        Automatic control for: ▪ Digital limit switch DES
        ▪ Mechanical limit switch NES
        Downloads
        TS + WS Overview (184.8 KiB)
        Catalogue sheet (2.9 MiB)
        Installation drawing (733.1 KiB)
        Installation instructions to 12/2019 (≤SW 1.2) (2.6 MiB)
        Installation instructions from 01/2020 (SW 3.0) (2.2 MiB)
        Installation instruction for the loop detector (203.9 KiB)
        Instructions to the GfA-Stick (1.3 MiB)
        Fault guide (331.2 KiB)
      • TS 971

        Technical data

        Technical data

        Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
        ▪ 3~230 V, PE; 3~400 V, PE
        Operating frequency: 50 Hz / 60 Hz
        Mains supply for
        external loads:
        24 V / 350 mA
        Dimensions W x H x D
        with mains switch:
        ▪ 155 x 386 x 90 mm
        ▪ 155 x 386 x 117 mm
        UBS modules: 2
        Relay contacts: 2
        Automatic control for: ▪ Digital limit switch DES
        ▪ Mechanical limit switch NES
        Downloads
        TS + WS Overview (184.8 KiB)
        Catalogue sheet (2.9 MiB)
        Installation drawing (733.1 KiB)
        UK TS971 connection instructions (3.4 MiB)
        Installation instructions from 01/2020 (SW 3.0) (4.1 MiB)
        Installation instruction for the WSD (1.2 MiB)
        Installation instruction for the loop detector (203.9 KiB)
        Instructions to the GfA-Stick (1.3 MiB)
        Fault guide (331.2 KiB)
      • TS 981

        Technical data

        Technical data

        Mains supply: ▪ 1N~230 V, PE; 3N~400 V, PE
        ▪ 3~230 V, PE; 3~400 V, PE
        Operating frequency: 50 Hz / 60 Hz
        Mains supply for
        external loads:
        24 V / 1000 mA
        Dimensions W x H x D: 190 x 300 x 115 mm
        UBS modules: 5
        Relay contacts: 2
        Control with traffic
        management for:
        Digital limit switch DES
        Downloads
        TS + WS Overview (184.8 KiB)
        Catalogue sheet (2.4 MiB)
        Installation drawing (311.6 KiB)
        Installation instructions (1.2 MiB)
        Installation instructions for folding doors (370.0 KiB)
        Status-Monitoring Module (155.3 KiB)
        Air-lock-function (145.7 KiB)
        OFF and Re-made module for air-lock (158.6 KiB)
        Fault guide (331.2 KiB)
      • TS 970-XL

        Technical data

        Technical data

        Mains supply: 3N~400 V
        Operating frequency: 50 Hz / 60 Hz
        Mains supply for
        external loads:
        24 V / 180 mA
        Dimensions W x H x D: 300 x 400 x 165 mm
        UBS modules: 1
        Relay contacts: 1
        Automatic control for: ▪ Digital limit switch DES
        ▪ Mechanical limit switch NES
        Features: ▪ Space for additional devices
        ▪ 4-pin main switch
        ▪ 3 DIN mounting rails
        ▪ 6 x M20 cable glands
        Downloads
        TS + WS Overview (184.8 KiB)
        Catalogue sheet (2.9 MiB)
        Installation drawing (864.4 KiB)
        Installation instructions to 12/2019 (≤SW 1.2) (2.6 MiB)
        Installation instructions from 01/2020 (SW 3.0) (2.2 MiB)
        Installation instruction for the loop detector (203.9 KiB)
        Instructions to the GfA-Stick (1.3 MiB)
        Fault guide (331.2 KiB)
      • TS 971-XL

        Technical data

        Technical data

        Mains supply: 3N~400 V
        Operating frequency: 50 Hz / 60 Hz
        Mains supply for
        external loads:
        24 V / 350 mA
        Dimensions W x H x D: 300 x 400 x 165 mm
        UBS moduels: 2
        Relay contacts: 2
        Automatic control for: ▪ Digital limit switch DES
        ▪ Mechanical limit switch NES
        Features: ▪ Space for additional devices
        ▪ 4-pin main switch
        ▪ 3 DIN mounting rails
        ▪ 6 x M20 cable glands
        Downloads
        TS + WS Overview (184.8 KiB)
        Catalogue sheet (2.9 MiB)
        Installation drawing (864.4 KiB)
        UK TS971 connection instructions (3.4 MiB)
        Installation instructions from 01/2020 (SW 3.0) (4.1 MiB)
        Installation instruction for the WSD (1.2 MiB)
        Installation instruction for the loop detector (203.9 KiB)
        Instructions to the GfA-Stick (1.3 MiB)
        Fault guide (331.2 KiB)
      • TS 981-XL

        Technical data

        Technical data

        Mains supply: 3N~400 V
        Operating frequency: 50 Hz / 60 Hz
        Mains supply for
        external loads:
        24 V / 1000 mA
        Dimensions W x H x D: 300 x 400 x 165 mm
        UBS modules: 5
        Relay contacts: 2
        Automatic control for: Digital limit switch DES
        Features: ▪ Space for additional devices
        ▪ 4-pin main switch
        ▪ 3 DIN mounting rails
        ▪ 6 x M20 cable glands
        Downloads
        TS + WS Overview (184.8 KiB)
        Catalogue sheet (2.4 MiB)
        Installation drawing (864.4 KiB)
        Installation instructions (1.2 MiB)
        Status-Monitoring Module (155.3 KiB)
        Air-lock-function (145.7 KiB)
        OFF and Re-made module for air-lock (158.6 KiB)
        Fault guide (331.2 KiB)
      • GfA-Stick

        Technical data

        Technical data

        Usage: The memory of the door control can be read out and displayed via Bluetooth® using the GfA-Stick and the GfA+ App.
        For door controls: ▪ TS 959
        ▪ TS 970
        ▪ TS 971
        ▪ TS 970-XL
        ▪ TS 971-XL
        Requirements: ▪ Mobile device with Bluetooth 4.0
        ▪ Installed GfA+ App
        Part no.: 20003696
        Downloads
        Technical data sheet (143.4 KiB)
        Instructions to the GfA-Stick (1.3 MiB)
  • Dock leveller controls

    Dock leveller controls

     

    Dock levellers are used for loading and unloading of vehicles. They allow a flexible height adjustment between building and cargo space of the vehicle.

    GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. In addition to the standard "extend and retract" functions, programmable relay contacts allow for numerous safety functions and other additional functions.

    • LB 700 for hinged wedge lip

      Controls for dock levellers with hinged wedge lip

      • LB 700 HL Standard

        Technical data

        Technical data

        Additional
        functions:
        ▪ Without
        Supply voltage: 3~230 V, PE / 3N~400 V, PE
        Operating frequency: 50 Hz
        P Hydraulic unit: 1,5 kW
        Valve voltage: 24 V DC
        Max. valve current: 1,0 A
        P traffic lights: 40 W
        P loading Zone lighting: 150 W
        Dimensions B x H x T: 189 x 254 x 143 mm

         

        Downloads
        Catalogue sheet LB 700 (688.0 KiB)
        Installation drawing (381.4 KiB)
        Installation instructions (363.7 KiB)
    • LB 700 for extendible lip

      Controls for dock levellers with extendible lip

      • LB 700 EL Standard

        Technical data

        Technical data

        Additional
        functions:
        ▪ Without
        Supply voltage: 3~230 V, PE / 3N~400 V, PE
        Operating frequency: 50 Hz
        P Hydraulic unit: 1,5 kW
        Valve voltage: 24 V DC
        Max. valve current: 1,0 A
        P traffic lights: 40 W
        P loading Zone lighting: 150 W
        Dimensions B x H x T: 189 x 254 x 143 mm

         

        Downloads
        Catalogue sheet LB 700 (688.0 KiB)
        Installation drawing (381.4 KiB)
        Installation instructions (363.7 KiB)
  • TS Dock leveller controls UK

    Dock leveller controls UK

    • Hinged Lip combined control device

      Controls for dock levellers with hinged wedge lip

      • HL combined control device

        Technical data

        Technical data

        Part: TS Control: Extra's
        CC61085 TS 959 None
        CC61099 TS 959 with mimic lights
        CC61100* TS 971 with mimic lights
        CC61181 TS 970 None
        CC61182 TS 971 None

        *ILLUSTRATED

        Downloads
        Datasheet (609.1 KiB)
        TS959 Installation Instructions (2.2 MiB)
        TS971 Instalation Instructions (3.1 MiB)
        TS970 Installation Instructions (2.6 MiB)
        LB700 Installation instructions (363.7 KiB)
    • Telescopic Lip combined control device

      Controls for dock levellers with extendible lip

      • TL combined control device

        Technical data

        Technical data

        Part: TS Control: Extra's:
        CC61160 TS 959 None
        CC61161 TS 959 with mimic lights
        CC61162 TS 971 with mimic lights

        *CC61100 ILLUSTRATED

        Downloads
        Datasheet (609.1 KiB)
        TS959 Installation Instructions (2.2 MiB)
        TS971 Instalation Instructions (3.1 MiB)
        LB700 Installation instructions (363.7 KiB)
    • TS + LB Custom length cables

      Custom length cables

      • Custom length cable w M40/M20 DES

        Technical data

        Technical data

        Part Number:   Part:   Description:
        20003955 00150   GE23955/015   1.5m cable with M40/M20 gland (DES)
        20003955 00300   GE23955/030   3m cable with M40/M20 gland (DES)
        20003955 00500   GE23955/050   5m cable with M40/M20 gland (DES)
        20003955 00700   GE23955/070   7m cable with M40/M20 gland (DES)
        20003955 00900   GE23955/090   9m cable with M40/M20 gland (DES)
        20003955 01300   GE23955/130   13m cable with M40/M20 gland (DES)

        Other lengths are available on request, please contact sales for more information

        Downloads
        Catalogue sheet (1.5 MiB)
      • Custom length cable w M40/M20 NES

        Technical data

        Technical data

        Part Number:   Part:   Description:
        20004117 00300   GE24117/030   3m cable with M40/M20 gland (NES)
        20004117 00500   GE24117/050   5m cable with M40/M20 gland (NES)
        20004117 00700   GE24117/070   7m cable with M40/M20 gland (NES)
        20004117 00900   GE24117/090   9m cable with M40/M20 gland (NES)
        20004117 01300   GE24117/130   13m cable with M40/M20 gland (NES)

        Other lengths are available on request, please contact sales for more information

        Downloads
        Catalogue sheet (1.5 MiB)
Subscribe to Newsletter

General Terms and Conditions of Purchase

General Terms of Sale and Delivery

Privacy Policy
Terms of use

Contact